We came across a small annoyance with Oracle product Reports developer 10g. We are yet to pin point the exact reasons, however, if you are experiencing the same issue which is as elaborated below:
Start Reports Developer 10g
Flash Screen appears
Then gets automatically minimized to the taskbar (Windows XP/7/8/8.1), and pointing the mouse shows the preview, as in below image.
However, clicking the preview window doesn’t bring up the Reports Builder 10g to maximized mode and remains unresponsive
Solution:
Right click the Preview window
and select “Maximize”
Once maximized, exit the reports developer. Restart to confirm the builder starts in Maximized mode next time.
Hope it helps!
If this not works for you try another solution mentioned below:
- Open the file named as "cauprefs.ora", located in "DevSuiteHome" directory.
- Search line"Reports.root_max = "
- Old value will be"Reports.root_max = No"
- Change this to"Reports.root_max = Yes"
Error: when report builder opens minimized
1: Location of file
3 comments:
One happy and grateful soul here. It works!
Thanks a lot!
-v-
It worked !! Thanks a lot.
With your explanation it was easy to solve .
Report works fine!
Thank you very much
Post a Comment